20 research outputs found

    Adsorption selectivity of CO2 over CH4, N2 and H2 in melamine-resorcinol-formaldehyde xerogels

    Get PDF
    Sorptive selectivity of melamine-resorcinol-formaldehyde xerogels, towards CO2, CH4, N2 and H2, is reported, where all systems demonstrate potential for selective adsorption of CO2 from corresponding binary gas mixtures. Selected gas mixtures represent important gas separation applications found in industry, i.e. CO2 removal from power plant flue gases (CO2-N2), sour gas sweetening (CO2-CH4), and separation of species in the water-gas shift reaction (CO2-H2). All materials tested exhibit microporous character, enhancing adsorption of small molecules, however, it is the inclusion of a nitrogen-rich material into the gel matrix that results in enhanced selectivities for these systems. Despite the porous character of the gels, under the test conditions used to simulate industrial parameters, all three balance gases, i.e. H2, N2 and CH4, showed low affinities for the xerogels, while CO2 adsorption was notably higher and increased with the inclusion and increased concentration of melamine. Ideal Adsorbed Solution Theory was used to demonstrate significant differences in adsorption uptake, especially for CO2-CH4, and high selectivities for CO2 over N2. In all cases, selected xerogels exhibited industrially relevant adsorption timescales for CO2 over competitor gases, demonstrating the potential of these materials for the selective adsorption of CO2 from process streams

    Parametric study of factors affecting melamine-resorcinol-formaldehyde xerogels properties

    Get PDF
    Resorcinol-formaldehyde (RF) xerogels are organic materials have been widely studied due to their industrially relevant characteristics, through which, RF gels have significant potential to be tailored to specific applications. Xerogel properties have been tailored, within this study, by altering the synthesis procedure with a focus on monomer concentrations, catalyst to monomer ratio, and the introduction of a nitrogen-rich precursor, thereby incorporating nitrogen into the structure to additionally affect the chemical properties of the final gel. Melamine (M) is used as the source of nitrogen, partially replacing the resorcinol (R) typically used, and resulting in a melamine-resorcinol-formaldehyde (MRF) gel; synthesis was facilitated by a sodium carbonate catalyst (C), as often used in RF gel production. R/C and R/F molar ratios, and M concentration ([M]), were chosen as parameters to study in-depth, as they have previously been shown to markedly influence sol-gel formation. The MRF gels produced were subsequently characterized to determine porous structure and chemical functionality. The results indicate that, texturally, increasing [M] produces a similar effect as increasing R/C values: increasing pore size, while decreasing surface area. Pore volume tends to increase when R/C or M increase individually but pore volume and surface area decrease drastically when both variables increase concurrently. Microporosity also tends to increase as R/C decreases, and as the concentration of M is decreased. Altering the gel matrix, by replacing M for R, results in a weakening of the gel structure, as the bridges formed during curing are reduced in quantity, which indicates a maximum level of substitution that can occur within these materials. Combined, these results suggest that nitrogen can be successfully incorporated into organic gel structures but that the interplay between process variables is crucial in determining final gel characteristics for specific applications

    Effect of s-triazine ring substitution on the synthesis of organic resorcinol-formaldehyde xerogels

    Get PDF
    Resorcinol (R) and formaldehyde (F) gel synthesis has been well-studied along with alternative reagents. We present the synthesis of formaldehyde-based xerogels using chemically similar s-triazine precursors, with comparison to traditional analogues. The substitution ranges from tri-hydroxyl to tri-amine, with an intermediate species, allowing changing chemistry to be investigated. Each molecule (X) offers different acid/base properties, known to influence gel formation, as well as differences in crosslinking potential. Varying X/F ratios were selected to recreate the stoichiometry used in RF systems, where one represented higher F to match the increased reaction sites of the additives. X/C ratios were selected to probe different catalyst (C) ratios, while working within the range likely to produce viable gels. Results obtained show little impact for ammeline as an additive due to its similarity to resorcinol (activation sites and pKa); while melamine and cyanuric acid show differing behavior depending on the level of addition. Low concentrations show melamine to have the most impact due to increased activation and competition for formaldehyde; while at high concentrations, cyanuric acid is shown to have the greatest impact as it creates a more acidic environment, which diminishes textural character, possibly attributable to larger clusters and/or weaker cross-linking of the system

    Decoupling microporosity and nitrogen content to optimise CO2 adsorption in modified xerogels

    Get PDF
    Selected melamine-resorcinol-formaldehyde (MRF) xerogels have been synthesised and analysed to determine the influence of nitrogen (N) incorporated into the gel structure, as well as, resorcinol to catalyst (sodium carbonate) and resorcinol to formaldehyde molar ratios. The aforementioned factors were varied, and their effect on gel properties characterised, allowing a better understanding of how gel characteristics can be tailored, and their impact on gel performance. MRF gels, produced in this study, were characterised using volumetric and gravimetric analyses to determine porous structure and quantify CO2 capture capacities and kinetics, as well as allowing determination of heats of adsorption and activation energies for CO2. MRF10_200_0.25 has exhibited the largest CO2 capacity (1.8mmol/g at 0 °C) of the sample tested. Thermal stability was tested by proximate analysis, and MRF xerogels exhibited high thermal stability, however it was found that volatile matter increases as [M] increases, particularly for [M] 20%w/w and higher. Working capacity was determined from a series of cycling studies and capacities of 0.55, 0.58 and 0.56 mmol/g at 60 °C were observed for [M] of 10, 20 and 30%w/w, respectively. The measured heat of adsorption showed that incorporation of nitrogen functionalities results in a low energy penalty demonstrating that the adsorption mechanism is still driven by physical forces. The results obtained indicate that the family of materials studied here offer potential routes for carbon capture materials, through a combination of micropore structure development and incorporation of favourable Lewis acid-base interactions

    Mortality and pulmonary complications in patients undergoing surgery with perioperative SARS-CoV-2 infection: an international cohort study

    Get PDF
    Background: The impact of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on postoperative recovery needs to be understood to inform clinical decision making during and after the COVID-19 pandemic. This study reports 30-day mortality and pulmonary complication rates in patients with perioperative SARS-CoV-2 infection. Methods: This international, multicentre, cohort study at 235 hospitals in 24 countries included all patients undergoing surgery who had SARS-CoV-2 infection confirmed within 7 days before or 30 days after surgery. The primary outcome measure was 30-day postoperative mortality and was assessed in all enrolled patients. The main secondary outcome measure was pulmonary complications, defined as pneumonia, acute respiratory distress syndrome, or unexpected postoperative ventilation. Findings: This analysis includes 1128 patients who had surgery between Jan 1 and March 31, 2020, of whom 835 (74·0%) had emergency surgery and 280 (24·8%) had elective surgery. SARS-CoV-2 infection was confirmed preoperatively in 294 (26·1%) patients. 30-day mortality was 23·8% (268 of 1128). Pulmonary complications occurred in 577 (51·2%) of 1128 patients; 30-day mortality in these patients was 38·0% (219 of 577), accounting for 81·7% (219 of 268) of all deaths. In adjusted analyses, 30-day mortality was associated with male sex (odds ratio 1·75 [95% CI 1·28–2·40], p\textless0·0001), age 70 years or older versus younger than 70 years (2·30 [1·65–3·22], p\textless0·0001), American Society of Anesthesiologists grades 3–5 versus grades 1–2 (2·35 [1·57–3·53], p\textless0·0001), malignant versus benign or obstetric diagnosis (1·55 [1·01–2·39], p=0·046), emergency versus elective surgery (1·67 [1·06–2·63], p=0·026), and major versus minor surgery (1·52 [1·01–2·31], p=0·047). Interpretation: Postoperative pulmonary complications occur in half of patients with perioperative SARS-CoV-2 infection and are associated with high mortality. Thresholds for surgery during the COVID-19 pandemic should be higher than during normal practice, particularly in men aged 70 years and older. Consideration should be given for postponing non-urgent procedures and promoting non-operative treatment to delay or avoid the need for surgery. Funding: National Institute for Health Research (NIHR), Association of Coloproctology of Great Britain and Ireland, Bowel and Cancer Research, Bowel Disease Research Foundation, Association of Upper Gastrointestinal Surgeons, British Association of Surgical Oncology, British Gynaecological Cancer Society, European Society of Coloproctology, NIHR Academy, Sarcoma UK, Vascular Society for Great Britain and Ireland, and Yorkshire Cancer Research

    Broadband multi-wavelength properties of M87 during the 2017 Event Horizon Telescope campaign

    Get PDF
    In 2017, the Event Horizon Telescope (EHT) Collaboration succeeded in capturing the first direct image of the center of the M87 galaxy. The asymmetric ring morphology and size are consistent with theoretical expectations for a weakly accreting supermassive black hole of mass ∼6.5 × 109Me. The EHTC also partnered with several international facilities in space and on the ground, to arrange an extensive, quasi-simultaneous multi-wavelength campaign. This Letter presents the results and analysis of this campaign, as well as the multi-wavelength data as a legacy data repository. We captured M87 in a historically low state, and the core flux dominates over HST-1 at high energies, making it possible to combine core flux constraints with the more spatially precise very long baseline interferometry data. We present the most complete simultaneous multi-wavelength spectrum of the active nucleus to date, and discuss the complexity and caveats of combining data from different spatial scales into one broadband spectrum. We apply two heuristic, isotropic leptonic single-zone models to provide insight into the basic source properties, but conclude that a structured jet is necessary to explain M87’s spectrum. We can exclude that the simultaneous γ-ray emission is produced via inverse Compton emission in the same region producing the EHT mm-band emission, and further conclude that the γ-rays can only be produced in the inner jets (inward of HST-1) if there are strongly particle-dominated regions. Direct synchrotron emission from accelerated protons and secondaries cannot yet be excluded.http://iopscience.iop.org/2041-8205am2022Physic

    Broadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity

    Get PDF
    Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user’s intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.peerReviewe

    Impact of Distance Determinations on Galactic Structure. II. Old Tracers

    No full text
    corecore